Any Question? We are Online... Ask Now

Fire Entry Suit EN1486



Fire Entry Suit Specifications
Outer Shell Made of special aluminised para-aramid blend fabric tested as per NFPA 1971 standard.
Second layer Aluminized Moisture Barrier
Third layer Special Heat treated inherently flame-retardant thermal barrier.
Inner layer Aramid/Kevlar non-woven laminated with PTFE membrane for maximum breathability and hydrostatic head(waterproof) performance
Inner layer Aluminized Moisture Barrier.
Inner layer Special Heat treated inherently flame-retardant thermal barrier
Inner layer Flame Retardant Lining (NFPA 2112 Certified)
Design & Features • Jacket & Trouser made aluminised para-aramid blend fabric having facility of B.A Set on back side.
• Pant are design high waist style, Suspenders with a width of 2 inches that can be adjusted. Leg bottoms have adjustable straps
• Five fingers hand gloves protection against the radiant heat.
• Hood consists of a very special grade glass visor which has Original 24 Carat Gold Vapour depositions in order to resist very high radiant heat.
• Overshoes: The shoes should have back side double fasting, and Velcro fasting belt for shoe inside the aluminised overcoat.
Weight: The weight of whole suit approximately 12 KG
Temperature resistance : Ambient Heat 815 °C
Aluminised radiant heat resist 1650°C
Radiant heat to 3000°F (1650°C) for Aluminized.
Certification : EN 1486 standard
NFPA 1971
NFPA 2112